Home battery payback
Does a home battery pay for itself? See bill savings from time-of-use rates and solar, and how much backup power must be worth. Free, runs in your browser.
A natural gas generator and a home battery both keep the lights on in an outage, so this compares what each costs a year, what each costs per outage hour covered, and whether either pays back in dollars.
At these inputs, over 15 years the generator costs about $1,157 a year and the battery about $933 a year. Per outage hour covered that is $313 and $252. Cover at $10 an hour is worth about $640 in total to each, so neither earns its cost back from outages alone. The break-even would be $271 an hour for the generator and $219 for the battery.
Three separate questions, three separate answers. They are not added into one score.
A whole-house generator can run far more than the load you entered. The battery only runs what the power box says, and it stops when it is empty.
| At these inputs | Generator | Battery |
|---|
Dollars only: the price, any rebate, running costs, and any unit bought again, less bill savings. No resale value, and no value for outage cover until the last two rows.
| Measure | Generator | Battery |
|---|
The same numbers with gas, service, bill savings and outage value held flat instead of rising.
| Measure | Generator, rising prices | Generator, flat prices | Battery, rising prices | Battery, flat prices |
|---|
Dollars only, per month. A minus sign means money going out. The last year includes a replacement if one is bought that year.
| Year | Generator | Battery |
|---|
Both lines start below zero at the price you pay. Neither climbs back to zero unless it saves money on your bill. Open the data table under the chart for the numbers.
The generator keeps going. The battery stops when its energy runs out.
Each input moved 25% down and 25% up. These are the two that move the gap between the two options the most.
Outage events a year are outage hours divided by hours in one outage. The generator covers every outage hour if the power you want is within its rating, and none if it is above it.
The battery keeps the share you choose for outages. It runs your load for that energy divided by the load, in hours. In each outage it covers the shorter of the outage length and that run time, and it covers nothing if the load is above the power it can supply at once.
Generator gas use is a straight line through the two published points, half load and full load. That straight line is an assumption. The weekly test run is priced at the gas use with no load, which is on the high side because the unit runs slowly. Gas cost is cubic feet times the price.
The battery saves on your bill only with the part it does not keep for outages. Solar moves in first, and each kilowatt-hour saves the grid price times the efficiency, less the export credit it gave up. On a time-of-use plan, each evening discharge saves the energy used times the peak price, less the energy needed to charge it times the off-peak price. A flat rate with no solar saves nothing.
Each option goes through the same cash-flow math: the price after any rebate, running costs and savings that rise by the yearly price rise, and the same price again in the year after a unit wears out. There is no resale value and no discount rate. Cost per outage hour covered is the net cost divided by the years times the hours covered a year. The break-even value of an outage hour is the net cost divided by all the covered hours, with the yearly rise, and it is the value at which cover alone would repay the cost.
The flat-price stress test runs the same math with the yearly rise set to 0. The two biggest changes come from moving outage hours, power to keep on, both prices, the gas price, the cost of an outage hour and (on a time-of-use plan) the peak gap by 25% each way, and comparing the net cost of each option after counting the value of cover.
Left out: resale value, battery fade (enter the end-of-life size to see the worst case), recharging a battery from solar during a long outage, a mix of outage lengths (every outage is the average length), the chance that a generator fails to start or a battery is low when the grid drops, home value, insurance, noise, fuel delivery, permits and local rules. Propane, diesel and portable units are not modeled; edit the gas boxes to try propane.
The sourced defaults were checked on 2026-10-17, and the table headed Benchmark sources and dates, further down this page, lists each one with its source. The battery cost and every value marked typical were not re-checked: typical values are round numbers we chose, so edit them. Prices and programs change, so confirm what applies to you.
Not found or not reachable on 2026-10-17: the cost of a battery per kWh (the NLR cost benchmark pages did not load, so the battery price is typical and not re-checked), a price for generator service, a primary figure for how long either lasts, and the New York state storage rebate (the NYSERDA site returned an error). The federal credit for home batteries is not assumed: the IRS page says the section 25D credit does not apply to spending after 2025-12-31, and it does not say whether a battery qualifies under another section.
This is a planning estimate, not tax, legal or medical advice. If you rely on a medical device, ask your provider about backup power. Confirm any rebate or credit with the IRS, NYSERDA or a tax professional.
Starting assumptions are example benchmarks, not binding quotes. Change any input to match your own bills or offers.
| Assumption / Input | Starting value | Source | Checked |
|---|---|---|---|
| Outage hours a year | 3.7 (New York), 10.2 (U.S.) | EIA Electric Power Annual, table 11.3 (2024, all events) | 2026-10-17 |
| Hours in one outage | 4.0 (New York), 6.7 (U.S.) | EIA Electric Power Annual, table 11.3 (2024, all events) | 2026-10-17 |
| Power to keep on | 1.5 kW (typical) | EIA FAQ on home electricity use | 2026-10-17 |
| Cost of an hour without power | $10 (typical) | LBNL Interruption Cost Estimate Calculator, as shown in a CPUC slide deck (2021-05-12) | 2026-10-17 |
| Years to compare | 15 years | typical, no source | 2026-10-17 |
| Yearly price rise | 2% a year | typical, no source | 2026-10-17 |
| Generator with installation | $12,700 | Consumer Reports, 5 Best Whole-House Generators of 2026 (updated 2026-07-28) | 2026-10-17 |
| Generator rebate | $0 | typical, no source | 2026-10-17 |
| Generator service and parts | $250 a year (typical) | Generac owner's manual, 9 kW to 22 kW air-cooled | 2026-10-17 |
| Generator life | 20 years (typical) | Generac 22 kW standby generator page | 2026-10-17 |
| Generator power | 21 kW | Generac 22 kW standby generator page | 2026-10-17 |
| Gas used at half and full load | 221 and 311 ft³ an hour | Generac 22 kW standby generator page | 2026-10-17 |
| Weekly test run | 5 minutes | Generac owner's manual, 9 kW to 22 kW air-cooled | 2026-10-17 |
| Natural gas price | $17.58 per 1,000 ft³ (New York), $15.34 (U.S.) | EIA residential natural gas price, New York; EIA residential natural gas price, U.S. | 2026-10-17 |
| Battery with installation | $14,000 | typical, no source | 2026-10-17 |
| Battery rebate or tax credit | $0 | IRS FAQs on Public Law 119-21 | 2026-10-17 |
| Battery energy and power | 13.5 kWh and 11.5 kW | Tesla Powerwall 3 datasheet; LBNL, U.S. Distributed Solar and Storage, 2026 Data Update | 2026-10-17 |
| Battery life | 15 years (typical) | Tesla Powerwall 3 datasheet | 2026-10-17 |
| Share kept full for outages | 100% | typical, no source | 2026-10-17 |
| Round-trip efficiency | 90% (typical) | Tesla Powerwall 3 datasheet | 2026-10-17 |
| Battery upkeep | $0 a year | typical, no source | 2026-10-17 |
| Time-of-use prices and discharges | $0.35 peak, $0.12 off-peak, 300 a year | typical, no source | 2026-10-17 |
| Price the grid charges you | $0.20 per kWh | EIA New York electricity profile | 2026-10-17 |
| Credit for exported solar | $0.08 per kWh | typical, no source | 2026-10-17 |